The following article will explain each and everything about Ruby laser that is  everything about the construction and working of Ruby laser:

The first laser to be operated successfully was ruby laser. First demonstration of laser action using ruby crystal was given by T.H. Maiman in 1960. It is a solid state laser.

Construction

Ruby is a crystal of aluminium oxide (Al2O3) in which some of the aluminium ions (Al3+) are replaced by chromium ions (Cr3+). This is done by doping small amounts of chromium oxide (Cr2O3) in the melt of purified Al2O3.

These chromium ions give the crystal a pink or red color depending upon the concentration of chromium ions. Laser rods are prepared from a single crystal of pink ruby which contains 0.05% (by weight) chromium. Al2O3 does not participate in the laser action. It only acts as the host.

The ruby crystal is in the form of cylinder. Length of ruby crystal is usually 2 cm to 30 cm and diameter 0.5 cm to 2 cm. As very high temperature is produced during the operation of the laser, the rod is surrounded by liquid nitrogen to cool the apparatus.

Active medium or active center: Chromium ions act as active centers in ruby crystal. So it is the chromium ions that produce the laser.

Pumping source: A helical flash lamp filled with xenon is used as a pumping source. The ruby crystal is placed inside a xenon flash lamp. Thus, optical pumping is used to achieve population inversion in ruby laser.

Optical resonator system: The ends of ruby crystal are polished, grounded and made flat. The one of the ends is completely silvered while the other one is partially silvered to get the output. Thus the two polished ends act as optical resonator system.

Note: Try to make the construction diagram yourself. In case of problem, contact me.

Working

Let us now discuss the working of ruby laser.

Ruby is a three level laser system. Suppose there are three levels E1, E2 and (E3 & E4). E1 is the ground level, E2 is the metastable level, E3 and E4 are the bands. E3 & E4 are considered as only one level because they are very closed to each other.

Pumping: The ruby crystal is placed inside a xenon flash lamp and the flash lamp is connected to a capacitor which discharges a few thousand joules of energy in a few milliseconds. A part of this energy is absorbed by chromium ions in the ground  state. Thus optical pumping raises the chromium ions to energy levels inside the bands E3 and E4. This process is called stimulated absorption. The transition to bands E3 and E4 are caused by absorption of radiations corresponding to wavelengths approximately 6600 angstroms and 4000 angstroms respectively. The levels inside the bands E3 and E4 are also known as pumping levels.

Achievement of population inversion: Cr3+ ions in the excited state loose a part of their energy during interaction with crystal lattice and decay to the metastable state E2. Thus, the transition from excited states to metastable state is non-radiative transition or in other words there is no emission of photons. As E2 is a metastable state, so chromium ions will stay there for longer time. Hence, the number of chromium ions goes on increasing in E2 state, while due to pumping , the number in the ground state E1 goes on decreasing. As a result, the number of chromium ions become more in excited state(metastable state) as compared to ground state E1. Hence, the population inversion is achieved between states E2 and E1.

Achievement of laser: Few of the chromium ions will come back from E2 to E1 by the process of spontaneous emission by emitting photons. The wavelength of a photon is 6943 Å. This photon travels through the ruby rod and if it is moving in a direction parallel to the axis of the crystal, then it is reflected to and fro by the silvered ends of the ruby rod until it stimulates  the other excited ions and cause it to emit a fresh photon in phase with the stimulating photon. Thus, the reflections will result in stimulated emission and it will result in the amplification of the stimulated emitting photons. This stimulated emission is the laser transition.

The two stimulated emitted photons will knock out more photons by stimulating the chromium ions and their total number will be four and so on. This process is repeated again and again, thus photons multiply. When the photon beam become sufficiently intense, then a very powerful and narrow beam of red light of wavelength 6943 Å emerges through the partially silvered end of the ruby crystal.

In the energy level diagram, E2 is the upper laser level and E1 is the lower laser level because laser beam is achieved in between these levels. Thus, the ruby laser fits into the definition of three level laser system.

Output: The output wavelength of ruby laser is 6943 Å and output power is 10 raise to power 4 to 10 raise to power 6 watts and it is in the form of pulses.

Note: Try to make the working diagram yourself. In case of problem, contact me.

Spiking in Ruby laser:

As we have discussed in working of ruby laser that the terminus of laser action is the ground state E1 in ruby laser. Therefore it is difficult to maintain the population inversion. This will result in the depletion of upper laser level E2 population (due to stimulated emission) more rapidly than it can be restored by the flash light that is optical pumping source. The laser emission is made up of spikes of high intensity emissions. This phenomenon is called spiking of the laser.

After the depletion of E2 state, the laser action ceases for a few microseconds. Since the flash lamp is still active, it again pumps the ground state chromium ions to upper level and again laser action begins. A series of such pulses is produced until the intensity of the flash light has fallen to such a level that it can no linger rebuild the necessary population inversion. So the output laser will be in the form of pulse in ruby laser or in other words, it will not be continuous.

Drawbacks of ruby laser

1. As the terminus of laser action is the ground state, it is difficult to maintain the population inversion. This fact results in ruby laser’s low efficiency.

2. The ruby laser requires high power pumping source.

3. The laser output is not continuous but occurs in the form of pulses of microsecond duration.

4. The defects due to crystalline imperfection are also present in ruby laser.

Uses of ruby laser

1. Ruby laser has very high output power of the order of 104 – 106 watts. It has wavelength of 6943 Angstroms.

2. Ruby lasers are used for holography, industrial cutting and welding.

Reference: This article is referred from my authored book “optics and lasers” having ISBN 81-272-2948-2. In case of any doubt, post in the comment section.